Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
G Ital Nefrol ; 40(2)2023 Apr 27.
Artigo em Inglês | MEDLINE | ID: covidwho-2314363

RESUMO

Background. Pregnant women are at high risk of Coronavirus disease 2019 (COVID-19) complications, including acute respiratory distress syndrome. Currently, one of the cornerstones in the treatment of this condition is lung-protective ventilation (LPV) with low tidal volumes. However, the occurrence of hypercapnia may limit this ventilatory strategy. So, different extracorporeal CO2 removal (ECCO2R) procedures have been developed. ECCO2R comprises a variety of techniques, including low-flow and high-flow systems, that may be performed with dedicated devices or combined with continuous renal replacement therapy (CRRT). Case description. Here, we report a unique case of a pregnant patient affected by COVID-19 who required extracorporeal support for multiorgan failure. While on LPV, because of the concomitant hypercapnia and acute kidney injury, the patient was treated with an ECCO2R membrane inserted in series after a hemofilter in a CRRT platform. This combined treatment reducing hypercapnia allowed LPV maintenance at the same time while providing kidney replacement and ensuring maternal and fetal hemodynamic stability. Adverse effects consisted of minor bleeding episodes due to the anticoagulation required to maintain the extracorporeal circuit patency. The patient's pulmonary and kidney function progressively recovered, permitting the withdrawal of any extracorporeal treatment. At the 25th gestational week, the patient underwent spontaneous premature vaginal delivery because of placental abruption. She gave birth to an 800-gram female baby, who three days later died because of multiorgan failure related to extreme prematurity. Conclusions. This case supports using ECCO2R-CRRT combined treatment as a suitable approach in the management of complex conditions, such as pregnancy, even in the case of severe COVID-19.


Assuntos
COVID-19 , Terapia de Substituição Renal Contínua , Gravidez , Humanos , Feminino , Dióxido de Carbono , Hipercapnia/terapia , Terapia de Substituição Renal Contínua/efeitos adversos , Circulação Extracorpórea/efeitos adversos , Circulação Extracorpórea/métodos , COVID-19/complicações , COVID-19/terapia , Placenta , Terapia de Substituição Renal/efeitos adversos
2.
Artif Organs ; 45(12): 1522-1532, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: covidwho-1526346

RESUMO

Disturbed oxygenation is foremost the leading clinical presentation in COVID-19 patients. However, a small proportion also develop carbon dioxide removal problems. The Advanced Organ Support (ADVOS) therapy (ADVITOS GmbH, Munich, Germany) uses a less invasive approach by combining extracorporeal CO2 -removal and multiple organ support for the liver and the kidneys in a single hemodialysis device. The aim of our study is to evaluate the ADVOS system as treatment option in-COVID-19 patients with multi-organ failure and carbon dioxide removal problems. COVID-19 patients suffering from severe respiratory insufficiency, receiving at least two treatments with the ADVOS multi system (ADVITOS GmbH, Munich, Germany), were eligible for study inclusion. Briefly, these included patients with acute kidney injury (AKI) according to KDIGO guidelines, and moderate or severe ARDS according to the Berlin definition, who were on invasive mechanical ventilation for more than 72 hours. In total, nine COVID-19 patients (137 ADVOS treatment sessions with a median of 10 treatments per patient) with moderate to severe ARDS and carbon dioxide removal problems were analyzed. During the ADVOS treatments, a rapid correction of acid-base balance and a continuous CO2 removal could be observed. We observed a median continuous CO2 removal of 49.2 mL/min (IQR: 26.9-72.3 mL/min) with some treatments achieving up to 160 mL/min. The CO2 removal significantly correlated with blood flow (Pearson 0.421; P < .001), PaCO2 (0.341, P < .001) and HCO 3 - levels (0.568, P < .001) at the start of the treatment. The continuous treatment led to a significant reduction in PaCO2 from baseline to the last ADVOS treatment. In conclusion, it was feasible to remove CO2 using the ADVOS system in our cohort of COVID-19 patients with acute respiratory distress syndrome and multiorgan failure. This efficient removal of CO2 was achieved at blood flows up to 300 mL/min using a conventional hemodialysis catheter and without a membrane lung or a gas phase.


Assuntos
COVID-19/terapia , Dióxido de Carbono/sangue , Circulação Extracorpórea/instrumentação , Pulmão/fisiopatologia , Insuficiência de Múltiplos Órgãos/terapia , Diálise Renal/instrumentação , Respiração Artificial , Idoso , COVID-19/sangue , COVID-19/diagnóstico , COVID-19/fisiopatologia , Estado Terminal , Circulação Extracorpórea/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência de Múltiplos Órgãos/sangue , Insuficiência de Múltiplos Órgãos/diagnóstico , Insuficiência de Múltiplos Órgãos/fisiopatologia , Diálise Renal/efeitos adversos , Respiração Artificial/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
3.
JAMA ; 326(11): 1013-1023, 2021 09 21.
Artigo em Inglês | MEDLINE | ID: covidwho-1441906

RESUMO

Importance: In patients who require mechanical ventilation for acute hypoxemic respiratory failure, further reduction in tidal volumes, compared with conventional low tidal volume ventilation, may improve outcomes. Objective: To determine whether lower tidal volume mechanical ventilation using extracorporeal carbon dioxide removal improves outcomes in patients with acute hypoxemic respiratory failure. Design, Setting, and Participants: This multicenter, randomized, allocation-concealed, open-label, pragmatic clinical trial enrolled 412 adult patients receiving mechanical ventilation for acute hypoxemic respiratory failure, of a planned sample size of 1120, between May 2016 and December 2019 from 51 intensive care units in the UK. Follow-up ended on March 11, 2020. Interventions: Participants were randomized to receive lower tidal volume ventilation facilitated by extracorporeal carbon dioxide removal for at least 48 hours (n = 202) or standard care with conventional low tidal volume ventilation (n = 210). Main Outcomes and Measures: The primary outcome was all-cause mortality 90 days after randomization. Prespecified secondary outcomes included ventilator-free days at day 28 and adverse event rates. Results: Among 412 patients who were randomized (mean age, 59 years; 143 [35%] women), 405 (98%) completed the trial. The trial was stopped early because of futility and feasibility following recommendations from the data monitoring and ethics committee. The 90-day mortality rate was 41.5% in the lower tidal volume ventilation with extracorporeal carbon dioxide removal group vs 39.5% in the standard care group (risk ratio, 1.05 [95% CI, 0.83-1.33]; difference, 2.0% [95% CI, -7.6% to 11.5%]; P = .68). There were significantly fewer mean ventilator-free days in the extracorporeal carbon dioxide removal group compared with the standard care group (7.1 [95% CI, 5.9-8.3] vs 9.2 [95% CI, 7.9-10.4] days; mean difference, -2.1 [95% CI, -3.8 to -0.3]; P = .02). Serious adverse events were reported for 62 patients (31%) in the extracorporeal carbon dioxide removal group and 18 (9%) in the standard care group, including intracranial hemorrhage in 9 patients (4.5%) vs 0 (0%) and bleeding at other sites in 6 (3.0%) vs 1 (0.5%) in the extracorporeal carbon dioxide removal group vs the control group. Overall, 21 patients experienced 22 serious adverse events related to the study device. Conclusions and Relevance: Among patients with acute hypoxemic respiratory failure, the use of extracorporeal carbon dioxide removal to facilitate lower tidal volume mechanical ventilation, compared with conventional low tidal volume mechanical ventilation, did not significantly reduce 90-day mortality. However, due to early termination, the study may have been underpowered to detect a clinically important difference. Trial Registration: ClinicalTrials.gov Identifier: NCT02654327.


Assuntos
Dióxido de Carbono/sangue , Circulação Extracorpórea , Respiração Artificial/métodos , Insuficiência Respiratória/terapia , Idoso , Término Precoce de Ensaios Clínicos , Circulação Extracorpórea/efeitos adversos , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Respiração Artificial/efeitos adversos , Síndrome do Desconforto Respiratório/terapia , Insuficiência Respiratória/mortalidade , Volume de Ventilação Pulmonar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA